罕见的IDG掉电导致翼上应急门灯亮

2023年6月有飞机报告空中出现IDG失效,随后反映左前和左后翼上应急门灯一直亮。自检PSEU当前有锁存信息52-72007 L FL SW FAULT 和52-72006 L FWD FL SW FAULT,清除锁存信息后左前和左后应急门灯熄灭。

此类事件机队首次出现,结合历史PSEU内部故障可能导致部分指示异常的的情况。分析是由于电流冲击,导致内部逻辑门触发了地信号所致。

关于一号风挡上的’tong mark’

SR 4-5795324831

2023年4月,在一号风挡更换工作中,发现新件在侧边框处有两个圆形的印迹,询问波音,表示为’tong mark’,在手册中描述如下,为制造过程中产生的,非缺陷。

The round marks shown in the ref /B/ attachment are not a defect.  This marks are normal and each is referred to as a ‘tong mark’.  Tong marks are defined and noted in the AMM.  Please refer to AMM Task 56-11-00-200-803 for definition of ‘Tong Marks’ and note in subtask 56-11-00-210-005.

2号风挡管控政策

各位领导,XX机x2号风挡裂纹,从左下点为初始点,向上延展,局部可见过热后的分层。从当前地面检查情况看,无潮气入侵,未有跳火的现象。针对此类问题,波音ISO-56-21-35989有多家航司曾反应过类似的问题,之前与PPG厂家做过面对面沟通,分析如下:

加温膜刷在中间层和外层玻璃之间,在风挡加热循环中膨胀。外层玻璃在制造过程中经过化学强化,因此在表面层具有可收缩性。空中时外层玻璃外表面暴露在环境温度下并收缩。但Z形槽和其他层玻璃不发生形变,从而抵抗外层玻璃外表面的变形。从而在边缘产生开裂。虽然厂家通过优化加温膜的工艺,以更好的使加温均匀,但还是有部分存在使用后衰退,局部加温不平衡的情况,因而产生此类无潮气入侵,也不跳火的裂纹。

从风挡结构的基本原理可以看出,风挡主要有三层,主要包括外层非结构玻璃层,中间乙烯基结构层和内层结构玻璃层。中间层和内层为主要承力结构,因此外层玻璃损坏不会对飞行安全造成影响,从AMM手册的检查要求也可以看出,只要裂纹不影响机组视线,在机组接受的情况下,可以按MEL保留加温放行飞机。

从机组检查单的要求,是当前风挡出现裂纹或破碎,关闭风挡加温,在1万英尺以下限制空速250节,若检查损伤出现在外层,则可继续正常操作,对飞行操作无影响。

当前737NG驾驶舱2#风挡主要措施如下:
1.航线工卡:现有航后工卡(JC-73N-AF-01)已包含风挡无明显损伤、裂纹、分层、过热、密封胶完好等检查。
2.A检:下发EO-73N-56-2020-002/EO-73N-56-2021-002 (T=R=550FH或800FH,注:不同客户A检间隔不一样)定期对驾驶舱各风挡及封严进行专项检查。检查内容包括划伤、缺口、裂纹、分层、跳火/电弧、气泡、封严胶破损/脱胶、潮气入侵等缺陷的详细检查。
3.C检出厂飞机风挡故障处理政策:要求发现问题的风挡必须在定检中完成处理,不允许办理保留或遗留未撤除的保留放行飞机。 4. EO-73N-30-2020-002 每1600FH执行2号风挡风挡加温系统检查。
5. 每周对风挡缺陷保留进行汇总评估,并对风挡缺陷进行评级,安排逐级更换。

统计至2022年11月22日的数据为

统计2012年以来机队2号风挡裂纹数据,总计28起,从风挡玻璃板的装机时间来看,最高32313FH,最低10FH,平均时间为11801FH,具体分布如下图所示。

从风挡玻璃失效的分布情况来看,数据较离散,无明晰的集中失效区或渐进衰变的特征。

从风挡历年来的裂纹情况统计,随着2018年起工程严控政策的实施,风挡裂纹万时率控制在历史较低的水平,整体运行平稳。

扩大看全机队的装机小时统计平均为11015,与机队严控政策有一定关系。

从历年拆换分布看,从2018年后,受严控影响,拆换的数量和千次率水平,整体高于历史平均水平。

波音的几次回复汇总:

Based on the pictures provided, the fracture pattern of the outer pane is consistent with the ‘thermal edge
break’ failure mode of which we have received a number of previous reports.
This type of failure appears to be the result of a heat control issue. Both Boeing and the supplier (PPG) agree
that these outer pane fractures may be attributed to a runaway heat condition which cause excessive thermal
stresses on the edge of the glass outer pane.
One possible cause that may lead to a runaway heat condition is a loss of insulation resistance between
ground and the temperature sensor. However, we have not been able to be confirm this because the
condition is not noticeable until the window overheats and outer pane fractures.

PPG统计的平均寿命

1号风挡管控措施

当前737NG驾驶舱1#风挡主要措施如下(注:整体管控措施在国内航司中偏严):
1. 航线工卡:现有航后工卡(QZ-AF-02)已包含风挡无明显损伤、裂纹、过热、密封胶完好等检查;
2. A检:下发EO-73N-56-2020-002/EO-73N-56-2021-002 (T=R=550FH或800FH,注:不同客户A检间隔不一样)定期对驾驶舱各风挡及封严进行专项检查。检查内容包括划伤、缺口、裂纹、分层、跳火/电弧、气泡、封严胶破损/脱胶、潮气入侵等缺陷的详细检查。
3.C检:下发EO-73N-56-2020-001 (T=R=不超过10000FH)定期详细检查风挡玻璃整圈封严胶状况并铲除后重新封胶,避免潮气入侵;
4.改装升级:依据737-SL-30-028下发EOCOM-30-0012升级WHCU至新件号83000-27904,避免WHCU在电源转换时导致风挡过热警告。机队受影响飞机均已完成。
5.风挡软时间更换:下发EO-COM-56-2020-002/EO-COM-56-2020-001 (T=R=不超过20000FH)定期更换(注:参考国内其他航司软时限政策制定)
6.风挡保留控制:保留组/技术团队制定机队飞机保留风险等级(高、中、低风险)清单、动态更新并计划性更换,其中对于中、高风险保留的风挡不予续保的管控政策。截止今日,1号风挡有6份FC,无高风险风挡保留。
7.C检出厂飞机风挡故障处理政策:要求发现问题的风挡必须在定检中完成处理,不允许办理保留或遗留未撤除的保留放行飞机。

8. 已下发MT20-737-56-049R1关于加强737飞机一号风挡编织导线和封严检查的维护提示。

二号风挡雨水管扎带松脱导致滴水

2022年3月,运行中有反应侧窗窗处余水管滴水,副驾地板上有部分水迹,经核实为余水管的扎带松脱;后续完成更换松脱的扎带,观察余水管不漏,清洁副驾地板水迹。驾驶舱顶部有一整块积水盘,用于收集内部形成的冷凝水,并排出机外。雨天一定层度上会导致内外温差大,机体内部容易产生冷凝水。这个滴水的点是与2号风挡相连的位置,通过扎带连接,扎带出现松动导致,目前有EO737-25-0957 检查驾驶舱2号风挡前方排水管 每800FH检查一次,借助本次案例,对工卡做了小的调整,要求检查管路松脱的情况。