2023年5月,有飞机反应左翼身过热灯在测试时不亮,按压灯泡和灯光测试正常,自检有32 KEEL BEAM信息,重装计算机无效。测量D742PIN9-PIN29为1.3M欧(手册要求是小于15欧)。重装D742自检正常无32信息,初步判断D742后方的线束有问题。对于64信息(初步判断为之前做M项,出的警告信息)。
状态信息1为SPOILER CONTROL CHANNEL ,相应维护信息为27-01330 GROUND SPOILER OUTPUT DRIVER SIGNAL IS OUT OF RANGE Detected by: SPOILER CONTROL ELECTRONICS (SCE);
状态信息2为GROUND SPOILER CONTROL,相应维护信息为27-01220 GROUND SPOILER CONTROL MODULE IS NOT IN COMMANDED POSITION Detected by: SPOILER CONTROL ELECTRONICS (SCE)。
RECOMMENDATION: 27-02790 SPOILER FAULT OUTPUT DRIVER SIGNAL IS OUT OF RANGE: Operators have reported SPOILER CONTROL CHANNEL status messages. Boeing finds these messages may occur during power up, often with maintenance message 27-02790.
To minimize the chance of dispatch delay, Boeing recommends to perform the following FIM based maintenance checks for occurrence of SPOILER CONTROL CHANNEL status message with MMsg 27-02790 (SPOILER FAULT OUTPUT DRIVER SIGNAL IS OUT OF RANGE): – Use the OMF to perform the ground test 27 – Spoiler Control OPERATIONAL TEST, SCE Test. -Refer to AMM Task 27-61-45-730-801 – Spoiler Control Electronics Self – Test. -Note that the SCE ground test requires the Master Dim and Test (MD&T) be in the bright (BRT) position. -Confirm the MMsg 27-02790 is cleared by the Ops Test. -If cleared, the system is OK for dispatch. -If the fault is still active, use FIM Task 27-61-00-810-922 to troubleshoot and diagnose the issue.
MEL dispatch relief is available for SPOILER CONTROL CHANNEL. MEL 27-61-01-01 should be reviewed for applicability.
MITIGATION: 27-02790 SPOILER FAULT OUTPUT DRIVER SIGNAL IS OUT OF RANGE: Boeing and the SCE supplier (BAE) are investigating the root cause of this message and assessing the appropriate Spoiler Control Electronics software change(s) to appropriately address these faults.
The EEC will set this message when the oil debris monitoring system (DMS) sensor is failed for 5 seconds.(a)This fault is only detected and annunciated by channel B.
代码为71-09001 “ONBOARD MAINTENANCE FUNCTION HAS NO INPUT FROM ENGINE-1 EEC”,737MAX-FTD-71-22002对该信息做过说明,如果将EEC置于TEST模式,则可以清除故障。同时波音建议如果发现MAINT灯亮,波音建议运营人 不要将MAINT灯与维护信息71-09001与/71-09011联系到一起,并采取进一步的排故来寻找MAINT灯亮的来源。